28,427 research outputs found

    Calibration results for the GEOS-3 altimeter

    Get PDF
    Data from the GEOS-3 altimeter were analyzed, for both the intensive and global modes, to determine the altitude bias levels for each mode and to verify the accuracy of the time tags which have been applied to the data. The best estimates of the biases are -5.30 + or - .2 m (intensive mode) and -3.55 m + or - .4 m (global mode). These values include the approximately 1.6 m offset of the altimeter antenna focal point from the GEOS-3 spacecraft center-of-mass. The negative signs indicate that the measured altitudes are too short. The data is corrected by subtracting the above bias numbers for the respective modes. Timing corrections which should be applied to the altimeter data were calculated theoretically, and subsequently confirmed through crossover analysis for passes 6-8 revolutions apart. The time tag correction that should be applied consists of -20.8 msec + 1 interpulse period (10.240512 msec)

    An experimental/analytical program to assess the utility of lidar for pollution monitoring

    Get PDF
    The development and demonstration of lidar techniques for the remote measurement of atmospheric constituents and transport processes in the lower troposphere was carried out. Particular emphasis was given to techniques for monitoring SO2 and particulates, the principal pollutants in power plant and industrial plumes. Data from a plume dispersion study conducted in Maryland during September and October 1976 were reduced, and a data base was assembled which is available to the scientific community for plume model verification. A UV Differential Absorption Lidar (DIAL) was built, and preliminary testing was done

    Optimization of sensor locations for measurement of flue gas flow in industrial ducts and stacks using neural networks

    Get PDF
    This paper presents a novel application of neural network modeling in the optimization of sensor locations for the measurement of flue gas flow in industrial ducts and stacks. The proposed neural network model has been validated with an experiment based upon a case-study power plant. The results have shown that the optimized sensor location can be easily determined with this model. The industry can directly benefit from the improvement of measurement accuracy of the flue gas flow in the optimized sensor location and the reduction of manual measurement operation with Pitot tube

    Appearance measurement system using fuzzy logic

    Get PDF
    To objectively measure the paint appearance on a car body the same as that perceived by customers, this paper presents a novel method to model the paint appearance using fuzzy logic. Three popular parameters, orange peel, metal texture effect and gloss, are used as system input, overall appearance is defined as system output. This fuzzy logic model is fully based on human understanding and expertise The preliminary result shows that this model can well mimic human behavior to reflect the correlation between overall appearance and individual properties of the paint surface

    A robot-based burr measurement system for the automotive industry

    Get PDF
    Burrs are often difficult to detect and measure because of their intrinsic variability in shape and dimension. No automotive standard had been established about their acceptable dimensions and measurement techniques for sheet steel products. For the automotive industry, even burrs of the size of 100 ÎĽm are perceived as damaging because of their dramatic impact upon panel corrosion resistance and assembly performance. It is critical to measure burrs during panel manufacture in order to control the process. The characterization of the typical burr produced has been carried out employing 3D measurements with a surface profilometer and a SEM. This analysis has shown a typical triangular burr shape and some characteristic dimensions. A contact method and two laser-triangulation systems have been developed. The instrument accuracy was analyzed, based upon a full factorial experimentation over a set of typical panels edges

    Investigation of potential of differential absorption Lidar techniques for remote sensing of atmospheric pollutants

    Get PDF
    The NASA multipurpose differential absorption lidar (DIAL) system uses two high conversion efficiency dye lasers which are optically pumped by two frequency-doubled Nd:YAG lasers mounted rigidly on a supporting structure that also contains the transmitter, receiver, and data system. The DIAL system hardware design and data acquisition system are described. Timing diagrams, logic diagrams, and schematics, and the theory of operation of the control electronics are presented. Success in obtaining remote measurements of ozone profiles with an airborne systems is reported and results are analyzed

    Lidar backscattering measurements of background stratospheric aerosols

    Get PDF
    A comparative lidar-dustsonde experiment was conducted in San Angelo, Texas, in May 1974 in order to estimate the uncertainties in stratospheric-aerosol backscatter for the NASA Langley 48-inch lidar system. The lidar calibration and data-analysis procedures are discussed. Results from the Texas experiment indicate random and systematic uncertainties of 35 and 63 percent, respectively, in backscatter from a background stratospheric-aerosol layer at 20 km

    A sensitivity analysis of volcanic aerosol dispersion in the stratosphere

    Get PDF
    A computer sensitivity analysis was performed to determine the uncertainties involved in the calculation of volcanic aerosol dispersion in the stratosphere using a 2 dimensional model. The Fuego volcanic event of 1974 was used. Aerosol dispersion processes that were included are: transport, sedimentation, gas phase sulfur chemistry, and aerosol growth. Calculated uncertainties are established from variations in the stratospheric aerosol layer decay times at 37 latitude for each dispersion process. Model profiles are also compared with lidar measurements. Results of the computer study are quite sensitive (factor of 2) to the assumed volcanic aerosol source function and the large variations in the parameterized transport between 15 and 20 km at subtropical latitudes. Sedimentation effects are uncertain by up to a factor of 1.5 because of the lack of aerosol size distribution data. The aerosol chemistry and growth, assuming that the stated mechanisms are correct, are essentially complete in several months after the eruption and cannot explain the differences between measured and modeled results

    A new list of thorium and argon spectral lines in the visible

    Get PDF
    Aims. We present a new list of thorium and argon emission lines in the visible obtained by analyzing high-resolution (R=110,000) spectra of a ThAr hollow cathode lamp. The aim of this new line list is to allow significant improvements in the quality of wavelength calibration for medium- to high-resolution astronomical spectrographs. Methods. We use a series of ThAr lamp exposures obtained with the HARPS instrument (High Accuracy Radial-velocity Planet Searcher) to detect previously unknown lines, perform a systematic search for blended lines and correct individual wavelengths by determining the systematic offset of each line relative to the average wavelength solution. Results. We give updated wavelengths for more than 8400 lines over the spectral range 3785-6915 A. The typical internal uncertainty on the line positions is estimated to be ~10 m/s (3.3 parts in 10^8 or 0.18 mA), which is a factor of 2-10 better than the widely used Los Alamos Atlas of the Thorium Spectrum (Palmer & Engleman 1983). The absolute accuracy of the global wavelength scale is the same as in the Los Alamos Atlas. Using this new line list on HARPS ThAr spectra, we are able to obtain a global wavelength calibration which is precise at the 20 cm/s level (6.7 parts in 10^10 or 0.0037 mA). Conclusions. Several research fields in astronomy requiring high-precision wavelength calibration in the visible (e.g. radial velocity planet searches, variability of fundamental constants) should benefit from using the new line list.Comment: 7 pages, 6 figures, accepted for publication in A&

    Numerical Evidence for the Observation of a Scalar Glueball

    Get PDF
    We compute from lattice QCD in the valence (quenched) approximation the partial decay widths of the lightest scalar glueball to pairs of pseudoscalar quark-antiquark states. These predictions and values obtained earlier for the scalar glueball's mass are in good agreement with the observed properties of fJ(1710)f_J(1710) and inconsistent with all other observed meson resonances.Comment: 12 pages of Latex, 3 PostsScript figures as separate uufil
    • …
    corecore